D.11.4. Feature "Reference substance - Update": How to update (edit) a Reference substance

Once a Reference substance has been created or imported (see chapter D.14 Import (import data from other IUCLID 5 systems)), it can be updated or edited from the Task panel.

D.11.4.1. Opening a Reference substance

To open a Reference substance, follow these steps:

  1. Go Home to the Task panel if you are not already there.

  2. Under Reference substance , click Update. A screen comes up with empty windows on the right side and a Query results pane on the left (below the title bar Navigation) showing all Reference substances in your IUCLID installation or the network you are connected to. The Reference substances are listed in alphabetical order.

  3. If you can easily find the desired Reference substance, just double-click it (left mouse button) to open it.

  4. In the case of a large number of Reference substances listed, run a query as described in the chapter D.11.4.2 Querying for a Reference substance in the Query results .

Note

If the list of Reference substances does not appear, check the query limit set in the User preferences (see chapter D.16.5.3 Tab "Query limit": Setting query limits ). If the User preferences menu cannot be displayed, contact the local IUCLID administrator.

Tip

From each entry in the query results list a context menu can be opened (right mouse click) as shown in the screenshot above. The context menu offers the following commands:

  • Open for opening the Reference substance (as an alternative method to double-click).

  • Print for printing the Reference substance.

  • Export for exporting the Reference substance.

  • Active reference substance for switching the status of the Reference substance e.g. from active to inactive .

  • Delete for deleting the Reference substance.

D.11.4.2. Querying for a Reference substance in the Query results

In the Query results pane, you can run a query as follows:

  1. Click into the Find / Filter pane below the Query title bar.

  2. Enter the Reference substance name or part of the name for the desired Reference substance. For example "chem" will filter out all Reference substances containing "chem" somewhere in the name. The more unequivocal the entered text is, the more the search for the desired Reference substance can be narrowed down.

    Tip

    Do not use * as a wildcard for truncated queries. Just enter any string (even part of the name). Queries are not case-sensitive. For detailed instruction on how to conduct queries in IUCLID, see chapter D.15 Query and search.

  3. Once you have found the desired Reference substance, double-click to open it. The user interface changes as the Reference substance section is displayed in the Data entry window together with the Information pane (see the screenshot below):

D.11.4.3. User interface of Reference substance: structure and elements

Once a Reference substance has been created or opened, the data entry window appears. The user interface is split into the following parts:

D.11.4.3.1. Data entry window

The data entry window displayed after creating/opening a Reference substance section consists of the following elements:

  • Title bar indicating the name of the Reference substance.

  • Data entry section.

Most data entry fields are self-explanatory, based on their labels and values in drop-down lists. For more detailed guidance, see the following subchapters.

Note

Details on how to specify the substance identity for REACH can be found in chapter 8 of the "Technical guidance document for identification and naming of substances in REACH (RIP 3.10)".

General information

Reference substance name: The Reference substance name displayed in this field is that previously entered and is read-only. Nevertheless it can be modified by clicking the Wizard button : a dialogue appears to assist you in performing the required steps.

Caution

Any change on the Reference substance name will have an impact on all associated data (e.g. Substance or Mixture dataset).

Note

If a name that already exists in the database is entered, a warning window comes up to ask for your confirmation. It is possible to proceed nevertheless, but it is strongly recommended not to enter identical Reference substance names in the IUCLID database (see the screenshot below).

EC inventory information

To create the link to the EC inventory, follow the steps:

  1. Click the Link button on the right side of the CAS number field. A query window appears.

  2. Enter your search criteria in order to retrieve all the matching entries in the EC-inventory stored in your IUCLID installation (wildcards such as * can be used - for detailed instructions on how to conduct queries in IUCLID see chapter D.15 Query and Search).

  3. Click the Search button to run the query. IUCLID returns a list of EC inventory entries meeting your search criteria.

  4. Select the desired EC inventory entry and Click the Assign button to create the link. Once the link is established, all relevant data from the EC inventory are automatically displayed. As they are read-only, the information cannot be modified. It is possible to delete the link to the EC inventory at any time and create a new one if appropriate.

Note

From the State column you can recognise whether the entry in the EC inventory is:

  • Active

  • Provisional

  • Obsolete

This state information was introduced to create the technical possibility to update and further maintain the EC inventory. EC inventory entries with the state ´obsolete´ should not be used.

Field name: Justification: In case there is no EC information available, select the justification from the drop-down list. Picklist options: || not yet assigned || NLP not notified || produced but not marketed (in EU) || research and development only || not applicable ||

Reference substance information

Set the confidentiality flag and specify the Regulatory purposes for all the information given in the following fields. For more details see chapter D.4.5.7 Flags used for filtering data.

CAS information

CAS number: When you establish the link with the EC inventory, this CAS number field is filled in automatically with the CAS number coming from the EC inventory. If you do not agree with it, you can change it with a CAS number of your choice.

CAS name: Insert a CAS name, if available.

IUPAC name

Insert a IUPAC name, if available.

Description

The description field provides the possibility to enter additional data needed to identify the substance.

Example: Specific additional main identifiers can be given for specific minerals, as minerals have characteristic physico-chemical properties which enable the completion of their identification, e.g.:

- Very low hardness for talc.

- Swelling capacity of bentonite.

- Shapes of diatomite (optical microscope).

- Very high density of barite.

- Surface area (nitrogen adsorption).

Synonyms

Insert the synonyms for the substance, by clicking the Insert row button .

Related CAS information

Add here any other related available CAS information:

Table D.5. Related CAS information

CAS nameSpecify the name in the CAS registration.
CAS numberInsert the CAS number.
Justification

Select one of the picklist options that describes the relation between the CAS number specified before and the related CAS information specified here.

Picklist options: || deleted || invalid || isomer || mixture of isomers || polymer || hydrated form || non-hydrated form || related to ||

If none of the pre-defined items applies, select other:. A text field is then activated next to the list field in which you can enter any free text.

Group / category information: Insert information about groups and categories the substance might belong to. The pre-filled reference substances might have indicating information about the DSL, OECD and USEPA categorisation if available.

Caution

This field is only to store related CAS information and not the actual CAS number and name of the substance. The correct CAS information applicable for the substance should not be specified in these fields. For this the individual fields CAS number and CAS name should be used.

Molecular and structural information

Set the confidentiality flag and specify the Regulatory purposes for all the information given in the following fields. For more details see chapter D.4.5.7 Flags used for filtering data.

Molecular formula: Insert molecular formula data.

Note

For REACH purposes, molecular formula shall be given in line with the Hill method. For more guidance on how to specify the substance identity for REACH, see chapter 8 of the "Technical guidance document for identification and naming of substances in REACH (RIP 3.10)".

Molecular weight range: Indicate the molecular weight (or the appropriate range). For more details see chapter D.4.5.5.1 Numeric range fields.

SMILES notation: Insert the SMILES notation.

The simplified molecular input line entry specification or SMILES is a specification for unambiguously describing the structure of chemical molecules using ASCII strings.

Example: Methanol has SMILES code: CO

Note

For well defined substance the molecular weight can be defined with a value e.g. the molecular weight of water (H2O) is 18.02 gram/mol. Certain substances like polymers have a distribution of the molecular weight. This distribution can be defined in IUCLID 5 by providing the information as a range. Additional information like the number average molecular weight (Mn) or the weight average molecular weight (Mw) - when relevant - should be described in the remarks field.

InChI: Insert the International Chemical Identifier (InChI), if known. The IUPAC International Chemical Identifier (InChI) is a non-proprietary identifier for chemical substances that can be used in printed and electronic data sources thus enabling easier linking of diverse data compilations notation. It was developed by IUPAC and NIST and is a digital equivalent of the IUPAC name for any particular covalent compound. Chemical structures are expressed in terms of five layers of information - connectivity, tautomeric, isotopic, stereochemical, and electronic.

Example: Ethanol has as InChI code InChI=1/C2H6O/c1-2-3/h3H,2H2,1H3

Structural formula: You can attach an image describing the chemical structural formula.

To attach an image file, follow the steps:

  1. Click the Load button .

  2. In the dialog appearing, specify the correct path by clicking the Look in button, the Up One level button or the Desktop button .

  3. In the Select files window, select the desired file. The image is displayed in the preview in the image preview window.

  4. Click the Open button to upload the file. A window comes up displaying the properties of the file (size and last date of modification). Enter appropriate remarks that specify the image file in addition to the file name.

  5. Click the Save button to complete the process.

Note

It is possible to attach image files in one of the four following formats:

  • *.gif

  • *.jpg (*.jpeg)

  • *.png

When the Open button is clicked, the selected image is automatically displayed in the data entry screen. It is possible to magnify the image by clicking the Zoom button or remove it by clicking the Delete button.

Remarks: If necessary provide here any additional comments.